Verificação de ligações parafusadas com chapa de extremidade estendida considerando as não linearidades do sistema
| dc.contributor.advisor | Cristina Almeida Magalhães | |
| dc.contributor.advisorLattes | http://lattes.cnpq.br/3127609568989733 | |
| dc.contributor.author | Viana, Guilherme Henrique Leite | |
| dc.contributor.authorLattes | http://lattes.cnpq.br/3232082700205235 | |
| dc.contributor.referee | Cristina Almeida Magalhães | |
| dc.contributor.referee | Sandro Cardoso Santos | |
| dc.contributor.referee | Pedro Américo Almeida Magalhães Júnior | |
| dc.date.accessioned | 2026-06-18T14:05:45Z | |
| dc.date.available | 2026-06-18T14:05:45Z | |
| dc.date.issued | 2023-11-03 | |
| dc.description.abstract | Estruturas em aço são comumente utilizadas em construções civis e em máquinas de grande porte existentes no setor de bens primários. Para a construção de tais estruturas é necessária a conexão entre os perfis estruturais e, um dos principais modos de conexão é através da ligação parafusada entre os componentes. Neste trabalho é apresentado um estudo do comportamento estrutural das ligações parafusadas com chapa de extremidade estendida, enfatizando a fundamentação teórica, os métodos de dimensionamento sugeridos por normas e a avaliação das ligações por meio de modelos computacionais. O objetivo desta pesquisa é o desenvolvimento de um modelo numérico considerando as não linearidades do sistema, validado por meio de testes experimentais, para comparação com as metodologias analíticas sugeridas por normas, a fim de avaliar as principais divergências entre o dimensionamento pelo método dos elementos finitos e pelos métodos normativos sugeridos pelo EUROCODE 3 (2005) e pela NBR 8800 (2008). Através dos diferentes modelos avaliados, com variação das dimensões de chapa e dos parafusos, pode-se levantar as principais divergências e pontos de atenção dos métodos normativos, além de se avaliar os modos de falha das ligações, os momentos máximos resistentes e a presença do efeito alavanca em alguns tipos de ligações estudados. | |
| dc.description.abstractother | Steel structures are commonly used in civil construction and large machinery. For the construction of such structures, it is necessary to joint the structural profiles and, one of the main modes of connection is through the bolted connection. This work presents a study of the structural behavior of extended end plate bolted connections, emphasizing the theoretical foundation, the design methods suggested by standards and the evaluation of connections through computational models. The objective of this research is the development of a numerical model considering the nonlinearities of the system, validated through experimental tests, for comparison with the analytical methodologies suggested by standards in order to evaluate the main divergences between the design by the finite element method and the normative methods suggested by EUROCODE 3 (2005) and NBR 8800 (2008). Through the different models evaluated, with variation of the dimensions of plate and screws, one can raise the main divergences and points of attention of the normative methods, in addition to evaluating the failure modes of the connections, the maximum resistant moments and the presence of the prying action in some types of connections studied. | |
| dc.identifier.uri | https://repositorio.cefetmg.br//handle/123456789/2750 | |
| dc.language.iso | pt | |
| dc.publisher | Centro Federal de Educação Tecnológica de Minas Gerais | |
| dc.publisher.country | Brasil | |
| dc.publisher.initials | CEFET-MG | |
| dc.publisher.program | Programa de Pós-Graduação em Engenharia Mecânica | |
| dc.subject | Ligações parafusadas – Teses | |
| dc.subject | Chapas de metal – Teses | |
| dc.subject | Método dos elementos finitos – Teses | |
| dc.subject | EN1993 Eurocódigo 3 (Padrão) – Teses | |
| dc.subject | Normas técnicas (Engenharia) – Teses | |
| dc.subject | Parafusos e porcas – Testes – Teses | |
| dc.title | Verificação de ligações parafusadas com chapa de extremidade estendida considerando as não linearidades do sistema | |
| dc.type | Dissertação |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- Verificação de ligações parafusadas com chapa de extremidade estendida considerando as não linearidades do sistema.pdf
- Tamanho:
- 4.02 MB
- Formato:
- Adobe Portable Document Format
Licença do Pacote
1 - 1 de 1
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.39 KB
- Formato:
- Item-specific license agreed to upon submission
- Descrição: