Proposta de adequação à Norma Regulamentadora NR-12: estudo de caso em máquina de manufatura de poliestireno expandido

dc.contributor.advisorMagalhães, Cristina Almeida
dc.contributor.advisorLatteshttp://lattes.cnpq.br/3127609568989733
dc.contributor.authorCosta, Gabriel Rodrigues da
dc.contributor.authorLatteshttp://lattes.cnpq.br/0932581127633369
dc.contributor.refereeMagalhães, Cristina Almeida
dc.contributor.refereeFelizardo, Ivanilza
dc.contributor.refereeAraújo, Marcelo Rios de
dc.date.accessioned2026-07-23T14:06:46Z
dc.date.available2026-07-23T14:06:46Z
dc.date.issued2026-06-18
dc.description.abstractA NR-12 estabelece requisitos técnicos e organizacionais destinados à prevenção de acidentes e à garantia da integridade física dos trabalhadores que interagem com máquinas e equipamentos industriais. Este trabalho apresenta uma proposta de adequação de uma máquina de manufatura de Poliestireno Expandido (EPS), especificamente a guilhotina de corte vertical a fio quente identificada como MG001, instalada em pátio fabril localizado na região metropolitana de Belo Horizonte. A pesquisa caracteriza-se como estudo de caso com abordagem qualitativa, estruturada a partir de pesquisa-ação, visita técnica ao equipamento, levantamento das condições operacionais e aplicação de metodologia de apreciação de riscos conforme diretrizes da ABNT NBR ISO 12100 e utilização do método Hazard Rating Number (HRN). Foram identificados riscos mecânicos e térmicos associados ao fio aquecido, ausência ou inadequação de proteções físicas, deficiência em dispositivos de parada de emergência, lacunas na sinalização de segurança e fragilidades nos procedimentos operacionais. Com base na análise realizada, foram determinadas a categoria de segurança e o Performance Level Requerido (PLr), conforme critérios da ABNT NBR ISO 13849-1, permitindo a proposição de medidas técnicas voltadas à mitigação dos riscos, incluindo instalação de proteções fixas e móveis com intertravamento, melhoria no arranjo físico, implementação de dispositivos de parada de emergência e adequação documental e de capacitação. Com base na projeção do cenário pós-adequação e nos novos valores estimados de HRN, verificou-se potencial de redução dos riscos identificados entre 60% e 90%, dependendo do cenário analisado. Esses resultados indicam que as medidas propostas podem contribuir significativamente para o aumento da segurança operacional, conformidade legal e melhoria das condições de trabalho. Conclui-se que a adequação sistematizada à NR-12 contribui para a redução de acidentes, melhoria das condições de trabalho e fortalecimento da cultura de segurança no ambiente industrial.
dc.description.abstractotherThe Brazilian Regulatory Standard NR-12 establishes technical and organizational requirements aimed at preventing occupational accidents and ensuring worker safety in the operation of machinery and equipment. This study presents a proposal for the safety compliance adaptation of an Expanded Polystyrene (EPS) manufacturing machine, specifically a vertical hot-wire cutting guillotine identified as MG001, installed in an industrial facility located in the metropolitan region of Belo Horizonte. The research is characterized as a qualitative case study structured through an action-research approach, including on-site technical inspection, operational condition assessment, and risk appraisal based on the guidelines of ABNT NBR ISO 12100. The Hazard Rating Number (HRN) method was applied to estimate and classify risk levels. Mechanical and thermal hazards associated with the heated wire were identified, as well as deficiencies related to physical guarding, emergency stop devices, safety signaling, and operational procedures. Based on the risk analysis, the required safety category and Performance Level (PLr) were determined according to ABNT NBR ISO 13849-1 criteria, enabling the proposal of engineering control measures focused on risk reduction. Suggested improvements include the installation of fixed and interlocked movable guards, enhancement of the physical layout, implementation of emergency stop systems, and updates to documentation and operator training programs. Based on the projected post-adaptation scenario and the new estimated HRN values, a potential reduction ranging from 60% to 90% in the identified risks was determined, depending on the evaluated scenario. The results suggest that the proposed measures can significantly enhance operational safety, ensure compliance with applicable regulations, and improve workplace conditions. It is concluded that systematic compliance with NR-12 strengthens workplace safety culture and contributes to sustainable industrial performance.
dc.identifier.urihttps://repositorio.cefetmg.br//handle/123456789/2850
dc.language.isopt
dc.publisherCentro Federal de Educação Tecnológica de Minas Gerais
dc.publisher.countryBrasil
dc.publisher.departmentDepartamento de Engenharia Mecânica
dc.publisher.initialsCEFET-MG
dc.subjectAvaliação de riscos – Teses
dc.subjectTrabalhadores da indústria – Normas – Teses
dc.subjectSegurança do trabalho – Teses
dc.subjectPoliestireno – Teses
dc.subjectSegurança industrial – Estatística – Teses
dc.titleProposta de adequação à Norma Regulamentadora NR-12: estudo de caso em máquina de manufatura de poliestireno expandido
dc.typeTrabalho de Conclusão de Curso da Graduação

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Proposta de adequação à Norma Regulamentadora NR-12- estudo de caso em máquina de manufatura de poliestireno expandido.pdf
Tamanho:
3.11 MB
Formato:
Adobe Portable Document Format
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.39 KB
Formato:
Item-specific license agreed to upon submission
Descrição: