Operação em regime permanente de linhas aéreas de transmissão otimizadas
dc.contributor.advisor | Afonso, Márcio Matias | |
dc.contributor.advisor-co | Silveira, Eduardo Gonzaga | |
dc.contributor.advisor-coLattes | http://lattes.cnpq.br/2888501805559990 | |
dc.contributor.advisorLattes | http://lattes.cnpq.br/2927636393829724 | |
dc.contributor.author | Melo, Marcílio Queiroz de | |
dc.contributor.authorLattes | http://lattes.cnpq.br/7426343954109782 | |
dc.contributor.referee | Afonso, Márcio Matias | |
dc.contributor.referee | Silveira, Eduardo Gonzaga | |
dc.contributor.referee | Coelho, Aurélio Luiz Magalhães | |
dc.contributor.referee | Schroeder, Marco Aurélio de Oliveira | |
dc.date.accessioned | 2025-05-28T11:59:10Z | |
dc.date.available | 2025-05-28T11:59:10Z | |
dc.date.issued | 2021-07-27 | |
dc.description.abstract | A análise operacional das Linhas Aéreas de Transmissão (LTs) recapacitadas permite dimensionar os seus aspectos qualitativos e técnicos. Este trabalho dedica-se a avaliar as condições operacionais, em regime permanente, de linhas recapacitadas por técnica LNPE – Linha de Transmissão de Potência Natural Elevada. As técnicas de recapacitação LNPE buscam alterar os parâmetros elétricos das linhas, tais como resistência, capacitância e indutância, objetivando o aumento da potência natural. Estas condições são obtidas por meio da otimização da posição dos condutores de fase. Para isso, três linhas aéreas de transmissão otimizadas, de diferentes níveis de tensão e configuração geométrica de condutores, são eletromagneticamente modeladas e comparadas às suas configurações reais e originais. O processo de modelagem parte do cálculo dos parâmetros elétricos das LTs, tais como impedância, capacitância e indutância, mediante suas características físicas e geométricas. De posse dos parâmetros elétricos das LTs é possível obter a potência natural destas linhas e simular diferentes modos de operação em regime permanente. As condições de operação a vazio, em curto-circuito e com carga das LTs recapacitadas são simuladas e comparadas às LTs originais. A vazio, o efeito Ferranti é atenuado em todos os níveis de tensão. Nos demais modos de operação, a corrente de curto-circuito e a queda percentual de tensão junto ao receptor são reduzidas. Os índices de desempenho e os parâmetros qualitativos das linhas, tais como os coeficientes de reflexão, o rendimento da transmissão, o consumo de reativo e a regulação de tensão são calculados para validação da avaliação de desempenho da técnica LPNE. De forma geral, as linhas LPNE apresentam ganhos operativos em regime permanente com consequentes vantagens econômicas. | |
dc.description.abstractother | The operational analysis of the retraining Transmission Lines (TLs) makes it possible to measure their qualitative and technical aspects. This work dedicates to evaluate the lines rebuilt by HSIL - High Surge Impedance Loading technique in a permanent regime operation. The HSIL retraining techniques seek to change the electrical parameters of the lines, such as resistance, capacitance and inductance. These conditions are obtained by optimizing the position of the phase conductors. For this, three optimized overhead transmission lines, with different voltage levels and geometric configuration of conductors, are electromagnetically modeled and compared to their real and original configurations. The modeling process starts from the calculation of the electrical parameters of the TLs, such as impedance, capacitance and inductance, based on their physical and geometric characteristics. With the electrical parameters of the TLs, it is possible to obtain the surge impedance of these lines and simulate different operation modes in steady state. The empty, short-circuit and loaded operating conditions of the TLs retraining are simulated and compared to the TLs original. When empty, the Ferranti effect is attenuated at all voltage levels. In the other operating modes, the short-circuit current and the percentage voltage drop at the receiver are reduced. The performance indexes and the qualitative parameters of the lines, such as the reflection coefficients, the transmission efficiency, the reactive consumption and the voltage regulation are calculated to validate the performance evaluation of the HSIL technique. In general, the HSIL lines show operating gains on a permanent regime with consequent economic advantages. | |
dc.identifier.uri | https://repositorio.cefetmg.br//handle/123456789/1589 | |
dc.language.iso | pt | |
dc.publisher | Centro Federal de Educação Tecnológica de Minas Gerais / Universidade Federal de São João del-Rei | |
dc.publisher.country | Brasil | |
dc.publisher.initials | CEFET-MG / UFSJ | |
dc.publisher.program | Programa de Pós-Graduação em Engenharia Elétrica | |
dc.subject | Linhas elétricas | |
dc.subject | Energia elétrica – Transmissão | |
dc.subject | Efeito de Ferranti | |
dc.subject | Sistemas de energia elétrica – Controle | |
dc.subject | Energia elétrica – Distribuição | |
dc.title | Operação em regime permanente de linhas aéreas de transmissão otimizadas | |
dc.type | Dissertação |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- Operação em regime permanente de linhas aéreas de transmissão otimizadas.pdf
- Tamanho:
- 2.24 MB
- Formato:
- Adobe Portable Document Format
Licença do Pacote
1 - 1 de 1
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.39 KB
- Formato:
- Item-specific license agreed to upon submission
- Descrição: