Análise térmica e eficiência energética de uma autoclave industrial
| dc.contributor.advisor | Souza, José Leôncio Fonseca de | |
| dc.contributor.advisorLattes | http://lattes.cnpq.br/0976210016960340 | |
| dc.contributor.author | Machado, Carlos Eduardo | |
| dc.contributor.referee | Souza, José Leôncio Fonseca de | |
| dc.contributor.referee | Lima, Frederico Romagnoli Silveira | |
| dc.contributor.referee | Barbieri, Paulo Eduardo Lopes | |
| dc.date.accessioned | 2026-07-22T16:26:48Z | |
| dc.date.available | 2026-07-22T16:26:48Z | |
| dc.date.issued | 2026-06-18 | |
| dc.description.abstract | Este Trabalho de Conclusão de Curso apresenta o desenvolvimento e a validação de um modelo térmico numérico tridimensional por Elementos Finitos (MEF) no software COMSOL Multiphysics 5.0, com o objetivo de analisar a distribuição energética de uma autoclave industrial Getinge modelo 6710 no seu platô de esterilização. A pesquisa foca em mapear os mecanismos de transferência de calor para o ambiente e avaliar o desempenho do sistema original de isolamento composto (lã de vidro e lã de rocha). A metodologia envolveu a simplificação geométrica do equipamento, a aplicação de condições de contorno de convecção natural e radiação, e a execução de testes de convergência de malha, sendo validada qualitativamente por medições, demonstrando excelente concordância e confirmando a robustez do modelo. O estudo identificou as regiões críticas de maior dissipação térmica devido à exposição de área superficial e comprovou a eficácia das camadas isolantes em reter o calor, permitindo concluir que o isolamento composto foi adequadamente dimensionado para o processo sob a ótica da conservação de energia. | |
| dc.description.abstractother | This Final Course Work presents the development and validation of a three-dimensional numerical thermal model using the Finite Element Method (FEM) in COMSOL Multiphysics 5.0 software, with the objective of analyzing the energy distribution of a Getinge model 6710 industrial autoclave during its sterilization plateau. The research focuses on mapping the heat transfer mechanisms to the environment and evaluating the performance of the original composite insulation system (glass wool and rock wool). The methodology involved the geometric simplification of the equipment, the application of natural convection and radiation boundary conditions, and the execution of mesh convergence tests, being qualitatively validated through field measurements using infrared thermography, demonstrating excellent agreement and confirming the robustness of the model. The study identified the critical regions of greatest thermal dissipation due to surface area exposure and proved the effectiveness of the insulating layers in retaining heat, allowing the conclusion that the composite insulation was adequately dimensioned for the process from the perspective of energy conservation. | |
| dc.identifier.uri | https://repositorio.cefetmg.br//handle/123456789/2845 | |
| dc.language.iso | pt | |
| dc.publisher | Centro Federal de Educação Tecnológica de Minas Gerais | |
| dc.publisher.country | Brasil | |
| dc.publisher.department | Departamento de Engenharia Mecânica | |
| dc.publisher.initials | CEFET-MG | |
| dc.subject | Autoclave – Equipamentos – Teses | |
| dc.subject | Calor – Transmissão – Teses | |
| dc.subject | Método dos elementos finitos – Teses | |
| dc.subject | Isolamento térmico – Teses | |
| dc.subject | Eficiência energética – Teses | |
| dc.title | Análise térmica e eficiência energética de uma autoclave industrial | |
| dc.type | Trabalho de Conclusão de Curso da Graduação |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- Análise térmica e eficiência energética de uma autoclave industrial.pdf
- Tamanho:
- 4.46 MB
- Formato:
- Adobe Portable Document Format
Licença do Pacote
1 - 1 de 1
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.39 KB
- Formato:
- Item-specific license agreed to upon submission
- Descrição: