Comparação de controladores ressonante e repetitivo para compensação de correntes harmônicas em inversores fotovoltaicos

dc.contributor.advisorPereira, Heverton Augusto
dc.contributor.advisorLatteshttp://lattes.cnpq.br/4298795970350194
dc.contributor.authorBarros, Victor Clévio de
dc.contributor.referee1Heverton Augusto Pereira
dc.contributor.referee2Marcelo Martins Stopa
dc.contributor.referee3Giovani Guimarães Rodrigues
dc.contributor.referee4Victor Flores Mendes
dc.date.accessioned2023-06-26T15:24:54Z
dc.date.available2023-06-26T15:24:54Z
dc.date.issued2018-09-21
dc.description.abstractA partir dos anos 70, o mundo percebeu sua enorme dependência por combustíveis fosseis. Nos anos posteriores, buscou-se tornar viáveis outras fontes de energias, principalmente renováveis. Neste contexto, sistemas fotovoltaicos começaram a ser desenvolvidos, como uma forma alternativa de geração de energia. Os sistemas fotovoltaicos não são totalmente utilizados em boa parte do dia e não são utilizados no período noturno. Assim, esses sistemas podem ser aproveitados nesses momentos para compensar correntes harmônicas indesejadas da rede elétrica, provenientes de cargas não lineares. Neste contexto, este trabalho apresenta um estudo comparativo com o controlador proporcional multi-ressonante e o controlador repetitivo, empregados em sistemas fotovoltaicos monofásicos conectados à rede elétrica durante a compensação de correntes harmônicas. As simulações propostas utilizam uma estrutura adaptativa de detecção de correntes harmônicas presente na rede elétrica. Para a detecção, são utilizadas estruturas SOGI (Second Order Generalized Integrator) e SRF-PLL (Synchronous Reference Frame- Phase Locked Loop) em cascata. O sistema utilizado foi projetado para um inversor de 4 kW, e para à compensação de correntes harmônicas de 3ª e 5ª ordem. O estudo possui três objetivos principais: avaliar o desempenho do Controlador Proporcional Multi-Ressonante na compensação de correntes harmônicas; avaliar o desempenho do Controlador Repetitivo na compensação de correntes harmônicas; e, por fim, comparar a capacidade de compensar correntes harmônicas de cada um desses controladores.
dc.description.abstractotherFrom the 1970s, the world realized its enormous dependence on fossil fuels. In the following years, other sources of energy, mainly renewable, were made viable. In this context, photovoltaic systems began to be developed as an alternative form of energy generation. Photovoltaic systems are not fully utilized for much of the day and are not used at night time. Thus, these systems can be used in these moments to compensate for unwanted harmonic currents of the electric power system, coming from non-linear loads. In this context, this work presents a comparative study on proportional resonant and repetitive controllers used in single-phase photovoltaic systems connected to the power system during the harmonic current compensation. The proposed simulations use an adaptive harmonic current detection structure. For the detection, Second Order Generalized Integrator (SOGI) and SRF-PLL (Synchronous Reference Frame-Phase Locked Loop) structures are used in cascade. The system used was designed for an inverter of 4 kW, and for the compensation of harmonic currents of 3° and 5° orders. The study has three main objectives: to evaluate the performance of the Multi-Resonant Proportional Controller in the compensation of harmonic currents; to evaluate the performance of the Repetitive Controller in the compensation of harmonic currents; and, finally, to compare the ability to compensate harmonic currents of each of these controllers.
dc.identifier.urihttps://repositorio.cefetmg.br/handle/123456789/338
dc.language.isopt
dc.publisherCentro Federal de Educação Tecnológica de Minas Gerais / Universidade Federal de São João del-Rei
dc.publisher.countryBrasil
dc.publisher.initialsCEFET-MG / UFSJ
dc.publisher.programPrograma de Pós-Graduação em Engenharia Elétrica
dc.subjectEnergia fotovoltaica
dc.subjectControladores elétricos - PID
dc.subjectEnergia elétrica - Qualidade
dc.titleComparação de controladores ressonante e repetitivo para compensação de correntes harmônicas em inversores fotovoltaicos
dc.typeThesis
dspace.entity.type

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Comparacao de controladores ressonante e repetitivo para compensacao de correntes harmonicas em inversores fotovoltaicos_Dissertacao.pdf
Tamanho:
3.12 MB
Formato:
Adobe Portable Document Format
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed to upon submission
Descrição: