Estudo da ocorrência e análise do fluxo retrógrado no canhão da cânula do cateter venoso curto periférico

dc.contributor.advisorSousa, Alexandre Rangel de
dc.contributor.advisor-coCosta Júnior, Ezequiel de Souza
dc.contributor.advisor-coLatteshttp://lattes.cnpq.br/8108524028271329
dc.contributor.advisorLatteshttp://lattes.cnpq.br/9897600291568251
dc.contributor.authorGoulart, Maria Luisa de Oliveira
dc.contributor.authorLatteshttp://lattes.cnpq.br/3014165796820875
dc.contributor.refereeMoravia, Weber Guadagnin
dc.contributor.refereeBraga, Luciene Muniz
dc.date.accessioned2025-04-28T14:44:58Z
dc.date.available2025-04-28T14:44:58Z
dc.date.issued2012-03-12
dc.description.abstractO cateter curto periférico é um instrumento médico hospitalar utilizado para punção venosa. Ele é composto por uma agulha de aço inoxidável e uma cânula de polímero. Sabe-se que durante a operacionalidade do cateter existe o risco de escoamento sanguíneo externo pelo compartimento da cânula. Acredita-se que este fluxo retrógrado representa um problema de risco biológico para os profissionais de saúde. Dentro deste contexto o principal objetivo da pesquisa é estudar a ocorrência de fluxo sanguíneo retrógrado na parte distal do canhão da cânula do cateter curto periférico. A metodologia para investigação deste evento envolveu a revisão da literatura, estudo da ocorrência de fluxo sanguíneo retrógrado através da cânula, investigação do tempo operacional, análise da quantidade de vazão sanguínea pela equação de Poiseuille e aplicação de um questionário a respeito da opinião de profissionais da área sobre o tema. De 52 observações 27% evidenciaram escoamento na saída da cânula no ato da punção venosa. A faixa de volume de sangue estimado nas operações foi de 10,2 mL a 7,12 mL para agulha de calibre 22G e 11,9 mL a 42,7 mL para agulha de calibre 21G.
dc.description.abstractotherThe peripheral short catheter is a medical instrument used for venipuncture hospital. It consists of a stainless steel needle cannula and a polymer. It is known that during the operation of the catheter there is a risk of blood flow compartment the outer cannula. It is believed that this retrograde flow is a problem of biological risk for health professionals. Within this context the main objective is to study the occurrence of retrograde blood flow in the distal part of the cannon tube short peripheral catheter. The research methodology for this event involved a literature review, study of the occurrence of retrograde blood flow through the cannula, the investigation of operating time, analyzing the amount of blood flow by Poiseuille equation and a questionnaire about the opinion of professionals area on the subject. 27% of 52 observations showed the flow leaving the tube at the time of venipuncture. The range of the estimated blood volume was 10.2 mL operations to 7.12 mL to 22G needle and 11.9 mL to 42.7 mL for size 21G needle.
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de Minas Gerais (FAPEMIG)
dc.identifier.urihttps://repositorio.cefetmg.br//handle/123456789/1293
dc.language.isopt
dc.publisherCentro Federal de Educação Tecnológica de Minas Gerais
dc.publisher.countryBrasil
dc.publisher.initialsCEFET-MG
dc.publisher.programPrograma de Pós-Graduação em Engenharia de Materiais
dc.subjectCatéteres
dc.subjectCateterismo venoso periférico
dc.subjectBiomateriais
dc.titleEstudo da ocorrência e análise do fluxo retrógrado no canhão da cânula do cateter venoso curto periférico
dc.typeDissertação

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Estudo da ocorrência e análise do fluxo retrógrado no canhão da cânula do cateter venoso curto periférico.pdf
Tamanho:
1.2 MB
Formato:
Adobe Portable Document Format
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.39 KB
Formato:
Item-specific license agreed to upon submission
Descrição: