Modelo matemático e estatístico para o mapeamento do volume morto no interior do distribuidor de lingotamento contínuo

dc.contributor.advisorNeves, Leonardo
dc.contributor.advisor-coBraga, Bernardo Martins
dc.contributor.advisor-coLatteshttp://lattes.cnpq.br/4321217480630520
dc.contributor.advisorLatteshttp://lattes.cnpq.br/0174392273282011
dc.contributor.authorRocha, Devans Gomes
dc.contributor.authorLatteshttp://lattes.cnpq.br/0230221947298865
dc.contributor.refereeNeves, Leonardo
dc.contributor.refereeSilva, Ernane Rodrigues da
dc.contributor.refereeFerreira, André Guimarães
dc.date.accessioned2025-03-16T23:39:33Z
dc.date.available2025-03-16T23:39:33Z
dc.date.issued2022-07-01
dc.description.abstractO presente estudo utilizou a modelagem matemática aliada aos métodos de obtenção das curvas de Distribuição de Tempo de Residência (DTR) para simular o modelo físico de um distribuidor em escala 1:5. Foram realizadas três simulações: sem injeção de gás, com injeção de gás em uma posição e com injeção de gás em quatro posições. O método de dispersão de traçador por pulso foi utilizado para análise da curva DTR permitiu uma análise do escoamento do aço líquido para a obtenção das frações de volume pistonado, de mistura e morto, para validação dos resultados foi utilizado dados obtidos no modelo físico do distribuidor. Os métodos de distribuições de probabilidade e transformações logarítmicas de dados foram utilizados para realizar o mapeamento de volume estagnado ou "morto" no distribuidor, onde velocidades máximas que caracterizam o volume morto foram definidas. Esse mapeamento permitiu propor uma nova configuração de injeção de gás com melhoria nos resultados de frações de volume.
dc.description.abstractotherThe present study used the mathematical modeling combined with the methods of obtaining the Residence Time Distribution (RTD) curves to simulate the physical model of a tundish in 1:5 scale. Three simulations were performed: without gas injection, with gas injection in one position and with gas injection in four positions. The tracer dispersion experiment was used to analyze the RTD curve, it allowed an analysis of the flow of liquid steel to obtain the fractions of plugged, mixing and dead volume, for validation of the results, data obtained from the physical model of the tundish was used. The methods of probability distributions and logarithmic transformations of data were used to perform the mapping of stagnant or "dead" volume in the tundish, where maximum velocities that characterize the dead volume were defined. This mapping allowed us to propose a new gas injection configuration with improved results for volume fractions.
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior – Brasil (CAPES) – Código de Financiamento 001
dc.identifier.urihttps://repositorio.cefetmg.br//handle/123456789/786
dc.language.isopt
dc.publisherCentro Federal de Educação Tecnológica de Minas Gerais
dc.publisher.countryBrasil
dc.publisher.initialsCEFET-MG
dc.publisher.programPrograma de Pós-Graduação em Engenharia de Materiais
dc.subjectFundição contínua - Modelos matemáticos
dc.subjectEstatística
dc.subjectFundição contínua - Processo - Análise
dc.subjectModelos matemáticos
dc.titleModelo matemático e estatístico para o mapeamento do volume morto no interior do distribuidor de lingotamento contínuo
dc.typeDissertação

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Modelo matemático e estatístico para o mapeamento do volume morto no interior do distribuidor de lingotamento contínuo.pdf
Tamanho:
2.88 MB
Formato:
Adobe Portable Document Format
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.39 KB
Formato:
Item-specific license agreed to upon submission
Descrição: