Análise do conforto térmico para usuários de uma moradia universitária e do desempenho térmico de sua envoltória
dc.contributor.advisor | Hirashima, Simone Queiroz da Silveira | |
dc.contributor.advisor-co | Oliveira, Raquel Diniz | |
dc.contributor.advisor-coLattes | http://lattes.cnpq.br/0005625273834609 | |
dc.contributor.advisorLattes | http://lattes.cnpq.br/3537026574860062 | |
dc.contributor.author | Pereira, Adriana Rodrigues | |
dc.contributor.referee1 | Simone Queiroz da Silveira Hirashima | |
dc.contributor.referee2 | Raquel Diniz Oliveira | |
dc.contributor.referee3 | Conrado de Souza Rodrigues | |
dc.contributor.referee4 | Camila Carvalho Ferreria | |
dc.date.accessioned | 2023-06-13T15:52:47Z | |
dc.date.available | 2023-06-13T15:52:47Z | |
dc.date.issued | 2019-02-05 | |
dc.description.abstract | As edificações devem atender a critérios de desempenho e conforto térmico de modo a minimizar o uso de sistemas de condicionamento de ar e a fornecer condições de habitabilidade satisfatórias. O presente trabalho tem como objetivo avaliar as condições de conforto térmico vivenciadas pelos usuários de uma moradia estudantil, naturalmente ventilada, localizada em Belo Horizonte - MG, e analisar o desempenho térmico de sua envoltória. Para realizar a avaliação referente ao conforto térmico, procedeu-se à análise de um quarto, localizado no último pavimento, considerando a situação mais desfavorável termicamente. A metodologia para avaliação do conforto térmico foi desenvolvida em três abordagens: (1) avaliação baseada no modelo adaptativo da ASHRAE 55 (ASHRAE, 2010); (2) avaliação baseada no modelo estático por meio dos índices PMV (voto médio estimado) e PPD (porcentagem de pessoas insatisfeitas) da ISO 7730 (2005); e (3) avaliação da percepção e preferência dos usuários mediante a aplicação de questionários. Para realizar a avaliação do desempenho térmico da envoltória, foram selecionados 7 quartos da moradia universitária, distintos em relação à orientação de suas aberturas e à localização em relação aos pavimentos. Um modelo computacional representativo da edificação foi elaborado com auxílio do software SketchUp e EnergyPlus e os quartos selecionados foram simulados. Foram investigadas possíveis modificações na envoltória, norteadas pelas recomendações da NBR 15220. Os dados obtidos para avaliação do conforto térmico apontaram correspondência entre as respostas dos usuários para a sensação térmica e os resultados obtidos utilizando o modelo adaptativo. Não houve aderência das respostas dos usuários com os resultados obtidos mediante a aplicação do modelo estático de conforto térmico. Em relação ao desempenho térmico, as simulações demonstraram a influência da envoltória no desempenho térmico da edificação avaliada e foi possível mensurar a diferença de desempenho entre as alternativas analisadas. Espera-se que os resultados obtidos neste trabalho possam nortear a elaboração de projetos de edificações que promovam o conforto térmico para os usuários e o desempenho de sua envoltória. | |
dc.description.abstractother | Buildings must meet criteria of performance and thermal comfort in order to provide satisfactory habitability conditions. Thus, it is essential to understand the factors affecting the building thermal performance and its thermal comfort. The present work aims to evaluate the thermal comfort conditions experienced by users of a student accommodation, naturally ventilated, located in Belo Horizonte, and analyze the thermal performance of its envelope. In order to to assess thermal comfort, it was chosen a room considered the most critical in relation to its thermal performance. The methodology for assessing thermal comfort was developed in three approaches: (1) evaluation based on the adaptive model of ASHRAE 55 (ASHRAE, 2010); (2) Evaluation based on the static model using the indices PMV (Predicted Mean Vote) and PPD (Predicted Percentage Dissatisfied) of ISO 7730 (2005); and (3) Assessment of users' perception and preference through the application of questionnaires. To carry out the thermal performance evaluation, 7 rooms were selected, distinct in relation to the orientation of its openings and the location. A representative computational model was elaborated in EnergyPlus and SketchUp softwares and the selected rooms were simulated. Possible modifications were investigated in the envelope, guided by the recommendations of NBR 15220 for the Bioclimatic Zone 3, in which is Belo Horizonte. Thus, it was possible to analyze the influence of some design parameters on the thermal behavior of the building. The results for thermal comfort indicated correspondence between the users' thermal sensation and the adaptive model. There was no adherence between users' thermal sensation and the static model for thermal comfort. Concerning the thermal performance, the simulations demonstrated the influence of the envelope on the thermal performance of the building. It is expected that the results obtained in this work guide projects that promote thermal comfort for the users and the thermal performance of the envelope. | |
dc.identifier.uri | https://repositorio.cefetmg.br/handle/123456789/262 | |
dc.language.iso | pt | |
dc.publisher | Centro Federal de Educação Tecnológica de Minas Gerais | |
dc.publisher.country | Brasil | |
dc.publisher.initials | CEFET-MG | |
dc.publisher.program | Programa de Pós-Graduação em Engenharia Civil | |
dc.subject | Conforto térmico | |
dc.subject | Ventilação natural | |
dc.subject | Simulação computacional | |
dc.title | Análise do conforto térmico para usuários de uma moradia universitária e do desempenho térmico de sua envoltória | |
dc.type | Thesis | |
dspace.entity.type |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- Analise do conforto termico para usuarios de uma moradia universitaria e do desempenho termico de sua envoltoria_Dissertacao.pdf
- Tamanho:
- 7.64 MB
- Formato:
- Adobe Portable Document Format
Licença do Pacote
1 - 1 de 1
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed to upon submission
- Descrição: