Avaliação da ventilação primária em tubos de queda e instalações sanitárias prediais em termos da NBR 8160
| dc.contributor.advisor | Santos, Hersília de Andrade e | |
| dc.contributor.advisorLattes | http://lattes.cnpq.br/3618369732101367 | |
| dc.contributor.author | Gonçalves, Nathália Verônica Ramos | |
| dc.contributor.authorLattes | http://lattes.cnpq.br/3370164427805659 | |
| dc.contributor.referee | Santos, Hersília de Andrade e | |
| dc.contributor.referee | Pereira, Isabela Labarrere Vieira | |
| dc.contributor.referee | Ferreira, Ivan Flávio | |
| dc.date.accessioned | 2026-10-16T19:21:33Z | |
| dc.date.available | 2026-10-16T19:21:33Z | |
| dc.date.issued | 2026-06-17 | |
| dc.description.abstract | A ventilação em sistemas prediais de esgoto sanitário exerce papel fundamental na manutenção do fecho hídrico dos desconectores e na prevenção do retorno de gases ao ambiente construído. Entretanto, em edificações de pequeno porte, a adoção da ventilação secundária ainda ocorre, muitas vezes, de forma conservadora, mesmo diante da possibilidade de utilização exclusiva da ventilação primária prevista pela ABNT NBR 8160:1999. Nesse contexto, esta pesquisa avaliou a suficiência da ventilação primária em tubos de queda de instalações sanitárias prediais de edificações com até cinco pavimentos, visando verificar a possibilidade de dispensa da ventilação secundária sem comprometimento do desempenho do sistema. A metodologia adotada caracterizou-se como quantitativa e analítica, fundamentada em revisão bibliográfica, análise normativa e estudo de caso. Foi desenvolvido um projeto hidrossanitário representativo, ao qual se aplicou o método de verificação do Anexo C da ABNT NBR 8160:1999 para análise das variáveis admissíveis e resultantes relacionadas à manutenção do fecho hídrico. Os resultados demonstraram que a depressão máxima resultante permaneceu inferior aos limites admissíveis estabelecidos pela norma, enquanto os efeitos de auto-sifonagem e sobrepressão foram considerados nulos nas condições adotadas. Além disso, a retirada da ventilação secundária proporcionou redução aproximada de 16% no quantitativo de conexões e acessórios e de 28% no comprimento total de tubulações. Conclui-se que, para a tipologia analisada, a ventilação primária mostrou-se suficiente para garantir o adequado funcionamento do sistema predial de esgoto sanitário, evidenciando potencial de racionalização construtiva e redução de materiais. | |
| dc.description.abstractother | Ventilation in building drainage systems plays a fundamental role in maintaining trap seals and preventing the return of sewer gases into indoor environments. However, in low-rise buildings, fully vented systems are often adopted conservatively, despite the possibility of using a single-stack system as permitted by ABNT NBR 8160:1999. In this context, this study evaluated the adequacy of stack venting in drainage stacks of buildings with up to five floors, aiming to verify the feasibility of eliminating relief venting without compromising system performance. The adopted methodology was quantitative and analytical, based on a literature review, normative analysis, and a case study. A representative sanitary plumbing design for Social Housing buildings was developed, and the verification method established in Annex C of ABNT NBR 8160:1999 was applied to analyze the admissible and resulting variables related to trap seal preservation. The results showed that the maximum resulting negative pressure remained below the admissible limits established by the standard, while self-siphonage and overpressure effects were considered null under the adopted conditions. In addition, eliminating relief venting resulted in an approximate reduction of 16% in fittings and accessories and 28% in the total pipe length. It was concluded that, for the analyzed building typology, stack venting was sufficient to ensure the proper functioning of the building drainage system, demonstrating potential for construction rationalization and material savings. | |
| dc.identifier.uri | https://repositorio.cefetmg.br//handle/123456789/3160 | |
| dc.language.iso | pt | |
| dc.publisher | Centro Federal de Educação Tecnológica de Minas Gerais | |
| dc.publisher.country | Brasil | |
| dc.publisher.department | Departamento de Engenharia Civil | |
| dc.publisher.initials | CEFET-MG | |
| dc.subject | Instalações hidráulicas – Normas | |
| dc.subject | Esgoto – Purificação – Aspectos ambientais | |
| dc.subject | Edificações – Tubulações de esgoto | |
| dc.subject | Gases – Escoamento | |
| dc.title | Avaliação da ventilação primária em tubos de queda e instalações sanitárias prediais em termos da NBR 8160 | |
| dc.type | Trabalho de Conclusão de Curso da Graduação |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- Avaliação da ventilação primária em tubos de queda e instalações sanitárias prediais em termos da NBR 8160.pdf
- Tamanho:
- 3.46 MB
- Formato:
- Adobe Portable Document Format
Licença do Pacote
1 - 1 de 1
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.39 KB
- Formato:
- Item-specific license agreed to upon submission
- Descrição: