Modelos de ajuste de curvas de extração para o cálculo de magnetização usando o software do magnetômetro SQUID Cryogenic S700X

dc.contributor.advisorPedroso, Emerson Fernandes
dc.contributor.advisorLatteshttp://lattes.cnpq.br/2158176306442308
dc.contributor.authorBarbosa, Daniel Antunes
dc.contributor.authorLatteshttp://lattes.cnpq.br/9489868259786696
dc.contributor.refereePedroso, Emerson Fernandes
dc.contributor.refereePatrício, Patrícia Santiago de Oliveira
dc.contributor.refereeLara, Luciano Roni Silva
dc.date.accessioned2025-04-08T17:17:09Z
dc.date.available2025-04-08T17:17:09Z
dc.date.issued2023-05-17
dc.description.abstractO interesse crescente, principalmente na física do estado sólido, pela caracterização de pequenas amostras ou amostras fracamente magnéticas, como filmes finos, fez desenvolver a tecnologia dos equipamentos de medição cujo estado da arte esta concentrada nos equipamentos dotados de sensores SQUID (dispositivo de interferência quântica supercondutor). Em medições de magnetização de alta sensibilidade, são comuns alguns desvios nas medidas que podem ocorrer devido a diversos fatores, dentre os quais podemos destacar os desvios decorrentes do tamanho e forma geométrica da amostra, efeitos na estrutura da amostra, deslocamento não controlado da amostra no porta-amostras, efeitos de expansão e contração térmicas do conjunto porta-amostras, ruídos magnéticos de origens diversas, dentre outras. Nesta pesquisa caracterizamos magneticamente uma amostra de óxido de disprósio Dy2O3, sobre a qual foram realizadas, em magnetômetro SQUID, medidas da magnetização em função do campo magnético aplicado como também medidas da magnetização em função da variação de temperatura. Neste segundo tipo de medição, geralmente as medidas são realizadas em uma faixa extensa de temperatura (5K a 300K), isto faz com que o porta-amostras e a haste que sustenta o porta-amostras sofram efeitos de expansão ou contração térmica, fazendo com que a amostra saia da posição correta na qual foi inicialmente colocada e devido a isto a medição apresente um desvio. O software que controla o equipamento possui três métodos para o tratamento das medidas de extração dos dados de magnetização. Estes métodos foram estudados a fim de verificar qual melhor se adequaria aos problemas apresentados nas medições, tais como os descritos acima, em especial o desvio devido à expansão ou contração térmica. O método de ajuste padrão do software (Multipol) em seu quarto grau foi suficiente para remover o desvio referente a contração/expansão do conjunto porta-amostras. Foi também estudado o método FITRMS, ao qual teve que ser calibrado previamente. Com este método de ajuste também foi possível remover os desvios nas medidas devido ao efeito de expansão térmica que ocorre no conjunto porta-amostras.
dc.description.abstractotherThe growing interest, mainly in solid state physics, for the characterization of small samples or weakly magnetic samples, such as thin films, led to the development of measuring equipment technology whose state of the art is concentrated in equipment equipped with SQUID sensors (quantum interference device superconductor). In high-sensitivity magnetization measurements, some deviations in the measurements are common and may occur due to several factors, among which we can highlight the deviations resulting from the size and geometric shape of the sample, effects on the structure of the sample, uncontrolled displacement of the sample in the sample holders, effects of thermal expansion and contraction of the sample holder set, magnetic noise from different sources, among others. In this research, we magnetically characterized a sample of Dy2O3 dysprosium oxide, on which magnetization measurements were performed in a SQUID magnetometer as a function of the applied magnetic field, as well as magnetization measurements as a function of temperature variation. In this second type of measurement, measurements are generally carried out over a wide temperature range (5K to 300K), this causes the sample holder and the rod that supports the sample holder to undergo thermal expansion or contraction effects, causing that the sample leaves the correct position in which it was initially placed and due to this the measurement presents a deviation. The software that controls the equipment has three methods for the treatment of magnetization data extraction measurements. These methods were studied in order to verify which one would best suit the problems presented in the measurements, such as those described above, in particular the deviation due to thermal expansion or contraction. The standard adjustment method of the software (Multipol) in its fourth degree was sufficient to remove the deviation related to the contraction/expansion of the sample holder set. The FITRMS method was also studied, which had to be previously calibrated. With this adjustment method it was also possible to remove deviations in the measurements due to the thermal expansion effect that occurs in the sample holder set.
dc.identifier.urihttps://repositorio.cefetmg.br//handle/123456789/1143
dc.language.isopt
dc.publisherCentro Federal de Educação Tecnológica de Minas Gerais
dc.publisher.countryBrasil
dc.publisher.initialsCEFET-MG
dc.publisher.programPrograma de Pós-Graduação Multicêntrico em Química de Minas Gerais
dc.subjectMagnetismo - Características
dc.subjectMagnetômetro
dc.subjectDispositivos supercondutores de interferência quântica
dc.subjectCurvas
dc.titleModelos de ajuste de curvas de extração para o cálculo de magnetização usando o software do magnetômetro SQUID Cryogenic S700X
dc.typeDissertação

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Modelos de ajuste de curvas de extração para o cálculo de magnetização usando o software do magnetômetro SQUID Cryogenic S700X.pdf
Tamanho:
1.08 MB
Formato:
Adobe Portable Document Format
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.39 KB
Formato:
Item-specific license agreed to upon submission
Descrição: