O Repositório será lançado oficialmente no dia 9 de abril de 2025 às 14h30min no miniauditório do Campus Nova Suiça.
 

Análise termoeconômica de um sistema de refrigeração em cascata que utiliza R744, ejetor e energia solar

dc.contributor.advisorBarbieri, Paulo Eduardo Lopes
dc.contributor.advisor-coFaria, Ralney Nogueira de
dc.contributor.advisor-coLatteshttp://lattes.cnpq.br/5541018219606187
dc.contributor.advisorLatteshttp://lattes.cnpq.br/9989399943912374
dc.contributor.authorMól, Débora Carla Silva
dc.contributor.authorLatteshttp://lattes.cnpq.br/4103835953260034
dc.contributor.refereeBarbieri, Paulo Eduardo Lopes
dc.contributor.refereeFaria, Ralney Nogueira de
dc.contributor.refereePaulino, Tiago de Freitas
dc.contributor.refereeOliveira, Raphael Nunes de
dc.date.accessioned2025-03-17T13:42:04Z
dc.date.available2025-03-17T13:42:04Z
dc.date.issued2023-11-24
dc.description.abstractEste trabalho analisou de forma ambiental e termoeconômica um Sistema de Refrigeração em Cascata com Ejetores (SRCE), que atua com energia solar e utiliza o R744 nos ciclos de baixa e média temperatura, operando de forma subcrítica, além do R600a, R1233zd(E) e o R141b avaliados no ciclo de alta temperatura. O modelo matemático foi implementado no software Engineering Equation Solver, considerando alguns parâmetros de entrada principais como, temperaturas do espaço de média e baixa temperatura, e valores de eficiência dos ejetores. Com isso, os resultados foram gerados considerando que para cada fluido refrigerante utilizado no ciclo de alta temperatura, os fluxos solares foram variados, assim como a área dos coletores, a temperaturas do gerador e a temperatura ambiente. A partir da simulação, observou-se que em temperaturas do ambiente mais baixas e temperaturas do gerador mais elevadas, o impacto ambiental medido pela parcela indireta do Total Equivalent Warming Impact, bem como o custo foram reduzidos, além dos melhores resultados do coeficiente de desempenho terem sido encontrados, destacando o R1233zd(E). O custo total otimizado apresentou uma redução de 48% por ano para o R1233zd(E) em relação à simulação, com um coeficiente de desempenho igual a 0,44. Portanto, aliando o desempenho termodinâmico, a questão ambiental e os custos, o R1233zd(E) apresentou as melhores características para operar no ciclo de alta temperatura do SRCE.
dc.description.abstractotherThis work analyzed the environmental and thermoeconomic aspects of a Cascade Refrigeration System with Ejectors (SRCE), which operates with solar energy and uses R744 in the low and medium temperature cycles, operating subcritically, in addition to R600a, R1233zd(E) and R141b evaluated in the high temperature cycle. The mathematical model was implemented in the Engineering Equation Solver (EES) software, considering some main input parameters such as medium and low temperature space temperatures, and ejector efficiency values. Thus, the results were generated considering that for each refrigerant used in the high temperature cycle, the solar irradiation were varied, as well as the collector area, the generator temperatures and the ambient temperature. From the simulation, it was observed that at lower ambient temperatures and higher generator temperatures, the environmental impact measured by the indirect portion of the Total Equivalent Warming Impact and the total cost were reduced, in addition to the best results of the coefficient of performance being found for R1233zd(E). The optimized total cost showed a reduction of 48% per year for R1233zd(E) in relation to the simulation, with a coefficient of performance of 0.44. Therefore, combining thermodynamic performance, environmental issues and costs, the R1233zd(E) had the best characteristics for operating in the high temperature cycle of SRCE applied.
dc.identifier.urihttps://repositorio.cefetmg.br//handle/123456789/802
dc.language.isopt
dc.publisherCentro Federal de Educação Tecnológica de Minas Gerais
dc.publisher.countryBrasil
dc.publisher.initialsCEFET-MG
dc.publisher.programPrograma de Pós-Graduação em Engenharia Mecânica
dc.subjectRefrigeração
dc.subjectAquecimento global
dc.subjectMecânica dos fluidos
dc.subjectEnergia solar
dc.titleAnálise termoeconômica de um sistema de refrigeração em cascata que utiliza R744, ejetor e energia solar
dc.typeDissertação

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Análise termoeconômica de um sistema de refrigeração em cascata que utiliza_Dissertacao.pdf
Tamanho:
3.22 MB
Formato:
Adobe Portable Document Format
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.39 KB
Formato:
Item-specific license agreed to upon submission
Descrição: