Avaliação da aderência entre barras finas de aço e concretos de diferentes classes de resistência

dc.contributor.advisorCarvalho, Eliene Pires
dc.contributor.advisorLatteshttp://lattes.cnpq.br/0426741711913176
dc.contributor.authorFernandes, Danielle Stefane Gualberto
dc.contributor.referee1Eliene Pires Carvalho
dc.contributor.referee2Edgar Vladimiro Mantilla Carrasco
dc.contributor.referee3Cláudio José Martins
dc.contributor.referee4Renata Gomes Lanna da Silva
dc.date.accessioned2023-06-07T15:06:54Z
dc.date.available2023-06-07T15:06:54Z
dc.date.issued2018-03-06
dc.description.abstractA aderência aço-concreto é um mecanismo de interação que possibilita a transferência de esforços das barras de aço para o concreto. Ela se mostra como uma das propriedades fundamentais em elementos de concreto armado. Para avaliação da aderência aço-concreto, os ensaios mais utilizados na literatura são: ensaios de arrancamento, ensaios de vigas rotuladas e ensaios de barras confinadas. Estudos anteriores apontam que o ensaio de barras confinadas mostra-se inadequado para barras finas de aço e que o ensaio de vigas rotuladas apresenta difícil execução. Já o ensaio de arrancamento mostra se como o mais simples e utilizado dos métodos para estudo do comportamento da aderência. No entanto, poucas pesquisas adotaram os ensaios de arrancamento para barras finas de aço (diâmetros de até 10,0 mm), que são normalmente utilizadas na construção civil, devido ao emprego cada vez maior do concreto de alta resistência e de elementos esbeltos. A norma brasileira ABNT-NBR 7480 (2007) requer um ensaio de aderência para controle de qualidade das barras. Portanto, atualmente há uma preocupação com os resultados dos ensaios para avaliar a aderência aço-concreto, principalmente para barras finas de aço. Dessa forma, o principal objetivo deste trabalho foi o estudo da aderência entre barras nervuradas finas (6,3 mm, 8,0 mm e 10,0 mm) e concretos convencional e de alta resistência (30 MPa e 60 MPa). Procurou-se, com esta pesquisa, contribuir para compreender melhor o comportamento da aderência aço-concreto para barras finas de aço e fornecer informações importantes para a definição de padrões futuros para ensaios de aderência. Para tanto, foram realizados ensaios de arrancamento de acordo com a EN:10080 (2005), adotando-se um comprimento de ancoragem modificado de 10 vezes o diâmetro da barra. Os resultados indicaram que a tensão de aderência aumenta com o aumento da resistência à compressão do concreto. Para concreto de alta resistência, concluiu-se que o diâmetro da barra não teria influência na tensão última de aderência. Quanto ao comprimento de ancoragem, são necessários mais ensaios para conclusões a respeito desse parâmetro. Em relação ao coeficiente de conformação superficial (η), os resultados apontaram valores próximos, independente do diâmetro da barra ou da classe de concreto.
dc.description.abstractotherThe steel-concrete bond is an interaction mechanism that enables force transfer of steel bars to concrete. It is one of the fundamental properties of reinforced concrete elements. Most of the tests used in the literature to evaluate the steel concrete bond are: pull-out tests, beam tests and confined bars tests. Previous studies indicated that confined bars test is inappropriate for thin steel bars and beam test is difficult to perform. The pull-out test is shown as the simplest and most common of the tests used for bond behavior study. However, there are few researches that have used the pull-out tests for thin steel bars (diameters up to 10.0 mm), which are commonly used in civil construction due to the increasing use of high-strength concrete and slender elements. The Brazilian standard ABNT-NBR 7480 (2007) requires a bond test for the rebars quality control. Therefore, there is currently a concern about the results from tests to evaluate the steel-concrete bond, especially for thin steel rebars. The main objective of this research was the study of the bond stress between thin deformed bars (6.3 mm, 8.0 mm and 10.0 mm) and conventional and high strength concrete (30 MPa and 60 MPa). The aim of this research was to contribute to a better understanding of the steel-concrete bond behavior for thin steel bars and to provide important information for the definition of future standards for bond tests. For that, pull-out tests were performed according to EN:10080 (2005), adopting a modified anchorage length equal to 10 times the bar diameter. The results indicated that the bond strength increased with the increase of concrete compressive strength. For high strength concrete, it was concluded that the diameter of the bar would have no influence on the ultimate bond strength. Regarding to the anchorage length, further tests are required for conclusions about this parameter. About the surface conformation coefficient (η), the results indicated close values, regardless of bar diameter or concrete class.
dc.identifier.urihttps://repositorio.cefetmg.br/handle/123456789/233
dc.language.isopt
dc.publisherCentro Federal de Educação Tecnológica de Minas Gerais
dc.publisher.countryBrasil
dc.publisher.initialsCEFET-MG
dc.publisher.programPrograma de Pós-Graduação em Engenharia Civil
dc.subjectConcreto de alta resistência
dc.subjectAncoragem (Engenharia de Estruturas)
dc.subjectAncoragem por aderência
dc.titleAvaliação da aderência entre barras finas de aço e concretos de diferentes classes de resistência
dc.typeThesis
dspace.entity.type

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Avaliacao da aderencia entre barras finas de aco e concretos de diferentes classes de resistencia_Dissertacao.pdf
Tamanho:
3.12 MB
Formato:
Adobe Portable Document Format
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed to upon submission
Descrição: