dc.description.abstractEste trabalho apresenta o projeto executivo de climatização e renovação de ar para a biblioteca do Campus Nova Gameleira do Centro Federal de Educação Tecnológica de Minas Gerais (CEFET-MG), edificação de uso institucional intenso que opera atualmente sem qualquer sistema de climatização instalado. O objetivo geral foi desenvolver o projeto contemplando o dimensionamento da carga térmica, a seleção do sistema de Volume de Refrigerante Variável (VRF), o dimensionamento do sistema dedicado de renovação de ar (DOAS) e a elaboração das plantas técnicas, visando garantir o conforto térmico e a qualidade do ar interior dos ambientes. O cálculo da carga térmica foi realizado pelo software HAP 6.2 da Carrier, com base no método Heat Balance Method (HBM) da ASHRAE, e resultou em uma carga total de resfriamento de 142,8 kW (40,6 TR), com pico em janeiro às 17 horas. A cobertura sem isolamento respondeu por 31,1% da carga sensível total, evidenciando o impacto da envoltória antiga sobre a demanda energética. O sistema VRF Midea V8 220V foi selecionado por meio do software Midea MCSSP, composto por duas unidades condensadoras combinadas (50 HP / 140 kW) e 19 unidades evaporadoras (13 cassetes de 4 vias e 6 mini cassetes), com taxa de combinação de 124,79% e EER de 3,88 kW/kW. O sistema DOAS foi dimensionado pelo método VRP da ASHRAE 62.1-2022 e dividido em duas máquinas independentes (MAQ-01 e MAQ-02), totalizando vazão de 917 L/s. Os dutos foram especificados em painéis MPU (alumínio pré-isolado com poliuretano), dimensionados pelo método da perda de carga constante. O orçamento total do projeto resultou em R$ 435.746,08, correspondendo a R$ 471,43/m² de área climatizada. Concluiu-se que o sistema VRF associado a DOAS constitui a solução técnica mais adequada para a edificação, tendo em vista a inviabilidade de instalação de chiller e os benefícios de eficiência energética em cargas parciais e controle individualizado por zona.
dc.description.abstractotherThis work presents the executive air-conditioning and ventilation project for the library of the Nova Gameleira Campus of the Federal Center for Technological Education of Minas Gerais (CEFET-MG), an institutional building of intense use currently operating without any air-conditioning system installed. The general objective was to develop the project including thermal load calculation, selection of the Variable Refrigerant Flow (VRF) system, sizing of the Dedicated Outdoor Air System (DOAS), and elaboration of the technical drawings, aiming to ensure thermal comfort and indoor air quality. The thermal load calculation was performed using Carrier's HAP 6.2 software, based on ASHRAE's Heat Balance Method (HBM), resulting in a total cooling load of 142.8 kW (40.6 TR), with peak in January at 5 PM. The uninsulated roof accounted for 31.1% of the total sensible load, highlighting the impact of the old envelope on the energy demand. The Midea V8 220V VRF system was selected through the Midea MCSSP software, composed of two combined condensing units (50 HP / 140 kW) and 19 evaporating units (13 four-way cassettes and 6 mini-cassettes), with a combination ratio of 124.79% and an EER of 3.88 kW/kW. The DOAS system was sized using the ASHRAE 62.1- 2022 VRP method and divided into two independent machines (MAQ-01 and MAQ-02), totaling 917 L/s. The ducts were specified in MPU panels (pre-insulated aluminum with polyurethane), sized using the equal friction method. The total project budget amounted to R$ 435,746.08, corresponding to R$ 471.43/m² of conditioned area. It was concluded that the VRF system associated with DOAS constitutes the most adequate technical solution for the building, considering the unfeasibility of installing a chiller and the benefits of energy efficiency at partial loads and individualized zone control.
dc.identifier.urihttps://repositorio.cefetmg.br//handle/123456789/2851
dc.language.isopt
dc.publisherCentro Federal de Educação Tecnológica de Minas Gerais
dc.publisher.countryBrasil
dc.publisher.departmentDepartamento de Engenharia Mecânica
dc.publisher.initialsCEFET-MG
dc.subjectAr condicionado – Belo Horizonte (MG) – Teses
dc.subjectMidea MCSSP (Software) – Teses
dc.subjectAnálise térmica – Carga – Teses
dc.subjectVentilação – Teses
dc.subjectBiblioteca Universitária – Projetos e construção – Teses
dc.titleProjeto de climatização e renovação de ar: dimensionamento e projeto executivo de climatização utilizando sistema VRF para a biblioteca do Campus Nova Gameleira do CEFET-MG
dc.typeTrabalho de Conclusão de Curso da Graduação

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Projeto de climatização e renovação de ar dimensionamento e projeto executivo de climatização utilizando sistema VRF para a biblioteca do Campus Nova Gameleira do CEFET-MG.pdf
Tamanho:
5.77 MB
Formato:
Adobe Portable Document Format
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.39 KB
Formato:
Item-specific license agreed to upon submission
Descrição: