O Repositório será lançado oficialmente no dia 9 de abril de 2025 às 14h30min no miniauditório do Campus Nova Suiça.
 

Controle de risco e gestão de pilhas de rejeito na mineração: estudo de caso

dc.contributor.advisorUrashima, Denise de Carvalho
dc.contributor.advisor-coUrashima, Beatriz Mydori Carvalho
dc.contributor.advisor-coLatteshttp://lattes.cnpq.br/3299701409478478
dc.contributor.advisorLatteshttp://lattes.cnpq.br/9870039269278664
dc.contributor.authorGonçalves, Beatriz Metelo
dc.contributor.authorLatteshttp://lattes.cnpq.br/0315859548779676
dc.contributor.refereeUrashima, Denise de Carvalho
dc.contributor.refereeUrashima, Beatriz Mydori Carvalho
dc.contributor.refereeGuimarães, Mag Geisielly Alves
dc.contributor.refereeCândido, Eduardo Souza
dc.date.accessioned2025-03-11T14:33:09Z
dc.date.available2025-03-11T14:33:09Z
dc.date.issued2023-12-11
dc.description.abstractA mineração tem um papel expressivo no desenvolvimento econômico do Brasil. Técnicas construtivas ineficientes ou problemas de manutenção na disposição dos rejeitos podem agravar o risco potencial de ruptura da estrutura de contenção, e acarretar consequências diretas ao meio ambiente, prejuízos econômicos e sociais. Diante deste cenário, o empilhamento drenado de rejeitos tem se mostrado atraente. Porém, as incertezas do comportamento dos solos sob cargas motivam a aplicação de análise de riscos. A ferramenta FMEA (Failure Mode and Effect Analysis) indica efetivamente os possíveis modos de falha de diferentes componentes de um sistema, e ainda, permite que os riscos sejam reconhecidos com intuito de estabelecer um plano de ação mais efetivo e integrado. O trabalho realizou uma análise de risco por meio da aplicação da metodologia FMEA em relação a etapa final da vida útil de uma pilha de disposição a seco de rejeitos. A pilha é composta por resíduos resultantes do beneficiamento de minério de zinco, principalmente constituída por areia fina siltosa, com uma baixa proporção de argila. O projeto da pilha definiu uma altura de cerca de 120 m e capacidade de armazenamento de aproximadamente 2 Mm³. Os componentes da pilha avaliados foram a fundação, o maciço principal e os sistemas de drenagem. Os principais modos de falha levantados foram: geração de excesso de poropressão, erosões e/ou trincas, depressões e abatimentos. Por fim, foi verificado na metodologia FMEA que ao realizar a análise de RPN e a classificação de criticidade na matriz, os riscos estavam predominantemente na faixa de toleráveis e aceitáveis, de forma a indicar que a estrutura deve continuar a ser monitorada por meio de instrumentações e inspeções rotineiras. Ressalta-se que a aplicação desse método demanda uma avaliação minuciosa e abrangente dos riscos, de formar a incorporar a análise do histórico da estrutura e de todas as informações disponíveis.
dc.description.abstractotherMining plays a significant role in Brazil's economic development. Inefficient construction techniques or maintenance problems in the disposal of waste can aggravate the potential risk of rupture of the containment structure, and lead to direct consequences for the environment, economic and social losses. Given this scenario, dry stacking of tailings has proven attractive. However, the uncertainties regarding the behavior of soils under loads motivate the application of risk analysis. The FMEA (Failure Mode and Effect Analysis) tool effectively indicates the possible failure modes of different components of a system, and also allows risks to be recognized in order to establish a more effective and integrated action plan. The work carried out a risk analysis through the application of the FMEA methodology in relation to the final stage of the useful life of a dry waste disposal pile. The pile is made up of waste resulting from the processing of zinc ore, mainly consisting of fine silty sand, with a low proportion of clay. The stack design defined a height of around 120 m and a storage capacity of approximately 2 Mm³. The main components of the pile evaluated were the foundation, the main foundation and the drainage systems. The main failure modes identified were: generation of excess pore pressure, erosions and/or cracks, depressions and subsidence. Finally, it was verified in the FMEA methodology that when carrying out the RPN analysis and criticality classification in the matrix, the risks were predominantly in the tolerable and acceptable range, indicating that the structure must continue to be monitored using instrumentation. And routine inspections. It should be noted that the application of this method requires a thorough and comprehensive assessment of the risks, in order to incorporate the analysis of the structure's history and all available information.
dc.identifier.urihttps://repositorio.cefetmg.br//handle/123456789/726
dc.language.isopt
dc.publisherCentro Federal de Educação Tecnológica de Minas Gerais
dc.publisher.countryBrasil
dc.publisher.departmentDepartamento de Engenharia Civil
dc.publisher.initialsCEFET-MG
dc.subjectAnálise de risco em mineração
dc.subjectDisposição de rejeitos
dc.subjectFailure Mode and Effect Analysis (FMEA)
dc.subjectEstabilidade de estruturas
dc.titleControle de risco e gestão de pilhas de rejeito na mineração: estudo de caso
dc.typeTrabalho de Conclusão de Curso da Graduação

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Controle de risco e gestão de pilhas de rejeito na mineração.pdf
Tamanho:
1.54 MB
Formato:
Adobe Portable Document Format
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.39 KB
Formato:
Item-specific license agreed to upon submission
Descrição: