Dimensionamento de um sistema manifold para uma instalação hidráulica (água fria e quente) com tubulação de CPVC
dc.contributor.advisor | Rodrigues, Valéria Antônia Justino | |
dc.contributor.advisorLattes | http://lattes.cnpq.br/8081307168629373 | |
dc.contributor.author | Silva, Flaviana Rodrigues da | |
dc.contributor.referee | Rodrigues, Valéria Antônia Justino | |
dc.contributor.referee | Aguiar, Thairone Conti Serafini | |
dc.contributor.referee | Batista, Luciana Teixeira | |
dc.date.accessioned | 2025-05-16T16:06:37Z | |
dc.date.available | 2025-05-16T16:06:37Z | |
dc.date.issued | 2025-02-18 | |
dc.description.abstract | As inovações tecnológicas executam um papel fundamental na modernização dos projetos de instalações hidráulicas de água fria e quente, fornecendo maior eficiência, segurança e sustentabilidade. O desenvolvimento de materiais como CPVC, PEX e PPR, bem como a aplicação de sistemas pressurizados e Manifold, são exemplos de melhorias que tornam as instalações mais eficientes e duráveis. Este trabalho objetivou o desenvolvimento de um projeto de sistema Manifold para uma instalação hidráulica de água fria e quente utilizando tubulação de CPVC. O sistema Manifold, identificado por um distribuidor central que abastece cada ponto de consumo por ramais individuais, fornece maior eficiência hidráulica, redução de perdas de carga e facilidade de manutenção em comparação com sistemas ramificados tradicionais. O estudo retratou os critérios de dimensionamento do sistema, considerando pressão, vazão e perda de carga, além das características do CPVC, um material amplamente utilizado devido à sua resistência térmica, durabilidade e facilidade de instalação. Por meio de cálculos e análises comparativas, o estudo demonstrou as vantagens técnicas do uso do Manifold com tubulação de CPVC em uma edificação residencial de padrão médio. Os resultados obtidos apontaram que a aplicação do sistema Manifold contribuiu para redução de custos com manutenções ao longo do ciclo de vida da edificação, pois reduziu as trocas de peças que apresentam baixa eficiência, como no caso de registros de gaveta, e apesar dos custos demonstrarem ser um pouco superior, em torno de 10,2% para aplicação do sistema com CPVC, este apresenta viabilidade técnica indiscutível. | |
dc.description.abstractother | Technological innovations play a key role in modernizing cold and hot water plumbing projects, providing greater efficiency, safety, and sustainability. The development of materials such as CPVC, PEX and PPR, as well as the application of pressurized and Manifold systems, are examples of improvements that make facilities more efficient and durable. This work aimed at the development of a Manifold system project for a hydraulic installation of cold and hot water using CPVC piping. The Manifold system, identified by a central distributor that supplies each point of consumption by individual branches, provides greater hydraulic efficiency, reduced head losses and ease of maintenance compared to traditional branched systems. The study portrayed the criteria for sizing the system, considering pressure, flow and pressure loss, in addition to the characteristics of CPVC, a widely used material due to its thermal resistance, durability, and ease of installation. Through calculations and comparative analyses, the study demonstrated the technical advantages of using Manifold with CPVC piping in an average residential building. The results obtained showed that the application of the Manifold system contributed to reducing maintenance costs throughout the building's life cycle, as it reduced the replacement of parts that present low efficiency, as in the case of drawer registers, and despite the costs proving to be a little higher, around 10.2% for the application of the system with CPVC, it presents indisputable technical feasibility. | |
dc.identifier.uri | https://repositorio.cefetmg.br//handle/123456789/1500 | |
dc.language.iso | pt | |
dc.publisher | Centro Federal de Educação Tecnológica de Minas Gerais | |
dc.publisher.country | Brasil | |
dc.publisher.department | Departamento de Engenharia Civil | |
dc.publisher.initials | CEFET-MG | |
dc.subject | Eficiência hidráulica | |
dc.subject | Dimensionamento de tubulações | |
dc.subject | Sistemas pressurizados | |
dc.title | Dimensionamento de um sistema manifold para uma instalação hidráulica (água fria e quente) com tubulação de CPVC | |
dc.type | Trabalho de Conclusão de Curso da Graduação |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- Dimensionamento de um sistema manifold para uma instalação hidráulica (água fria e quente) com tubulação de CPVC.pdf
- Tamanho:
- 4.63 MB
- Formato:
- Adobe Portable Document Format
Licença do Pacote
1 - 1 de 1
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.39 KB
- Formato:
- Item-specific license agreed to upon submission
- Descrição: