Análise comparativa de estações elevatórias de esgotocomdiferentes vazões e alturas manométricas
dc.contributor.advisor | Ribeiro Junior, Leopoldo Uberto | |
dc.contributor.advisor-co | Nogueira, Felipe Pires | |
dc.contributor.advisor-coLattes | http://lattes.cnpq.br/1653257251540646 | |
dc.contributor.advisorLattes | http://lattes.cnpq.br/4244310666833677 | |
dc.contributor.author | Souza, Thiago Antunes de | |
dc.contributor.referee | Ribeiro Junior, Leopoldo Uberto | |
dc.contributor.referee | Nogueira, Felipe Pires | |
dc.contributor.referee | Rodrigues, Valéria Antônia Justino | |
dc.contributor.referee | Faria, Flávia Castro de | |
dc.date.accessioned | 2025-03-11T14:30:40Z | |
dc.date.available | 2025-03-11T14:30:40Z | |
dc.date.issued | 2025-02-06 | |
dc.description.abstract | O presente trabalho tem como intuito a análise comparativa deestaçõeselevatórias de esgoto com diferentes vazões e alturas manométricas. Asestaçõeselevatórias de esgoto são componentes essenciais em sistemas de saneamentobásico, especialmente em regiões onde a topografia não permite a drenagemporgravidade até a estação de tratamento de esgoto. Com o estudo dereferenciaisteóricos em conjunto com as normas vigentes, pretende-se como desenvolvimentodeste o analisar de um modelo de estação elevatória de esgoto de formasimples,levando em conta parâmetros pré-definidos e critérios estipulados aodecorrerdotrabalho. No referencial teórico abordam-se alguns conceitos quesefazempresentes e necessários para elaboração de projeto de estações elevatóriasdeesgoto, como localização das estações elevatórias, classificações, tiposdebombeamentos, período de projeto, vazões de projeto, bombas, motores, etc. Nametodologia foram adotados parâmetros iniciais para modelagemde03(três)cenários de populações (100/1.000/10.000 habitantes) para alturas manométricastotais de 20 e 100 metros, assim obtendo 06 (seis) padrões distintos dedados,através da manipulação de dados por meio dos cálculos de vazões de contribuições,de diâmetros das tubulações, dos tempos de detenções hidráulicas, das velocidadesdos barriletes, dos volumes e áreas dos poços de sucção, etc. Os resultadosalcançados evidenciaram a influência da população e da altura manométricanopré-dimensionamento das estações elevatórias de esgoto, determinou-sequeoincremento da população demanda bombas de maior capacidade e estruturasdemaior porte, e simultaneamente que o acréscimo na altura manométricarequerbombas com maior potência e tubulações mais robustas no sistema. Aestudodepré-dimensionamento explanada mostrou bons resultados na determinaçãofinal dosconjuntos para cada cenário. | |
dc.description.abstractother | This study aims to perform a comparative analysis of sewagepumpingstations with different flow rates and manometric heights. Sewage pumpingstationsare essential components in basic sanitation systems, especially in regionswherethe topography does not allow gravity drainage to the sewage treatment plant. Bystudying theoretical references in conjunction with current standards, theaimof thisstudy is to analyze a sewage pumping station model in a simple way, takingintoaccount pre-defined parameters and criteria stipulated during the courseof thestudy.The theoretical reference addresses some concepts that are present andnecessaryfor the preparation of sewage pumping station projects, such as the locationof thepumping stations, classifications, types of pumping, design period, designflowrates,pumps, motors, etc. The methodology adopted initial parameters for modeling03(three) population scenarios (100/1,000/10,000 inhabitants) for total manometricheights of 20 and 100 meters, thus obtaining 06 (six) distinct data patterns, throughdata manipulation by means of calculations of contribution flows, pipediameters,hydraulic retention times, barrel velocities, volumes and areas of suctionwells, etc.The results achieved demonstrated the influence of the population andmanometricheight on the pre-sizing of sewage pumping stations. It was determinedthat theincrease in population demands higher capacity pumps and larger structures, andsimultaneously that the increase in manometric height requires higher power pumpsand more robust pipes in the system. The pre-sizing study explained showedgoodresults in the final determination of the sets for each scenario. | |
dc.identifier.uri | https://repositorio.cefetmg.br//handle/123456789/716 | |
dc.language.iso | pt | |
dc.publisher | Centro Federal de Educação Tecnológica de Minas Gerais | |
dc.publisher.country | Brasil | |
dc.publisher.department | Departamento de Engenharia Civil | |
dc.publisher.initials | CEFET-MG | |
dc.subject | Estações elevatórias de esgoto | |
dc.subject | Análise comparativa de vazões e alturas manométricas | |
dc.subject | Pré-dimensionamento de sistemas de saneamento | |
dc.subject | Engenharia sanitária | |
dc.title | Análise comparativa de estações elevatórias de esgotocomdiferentes vazões e alturas manométricas | |
dc.type | Trabalho de Conclusão de Curso da Graduação |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- Análise comparativa de estações elevatórias de esgotocomdiferentes vazões e alturas manométricas.pdf
- Tamanho:
- 5.04 MB
- Formato:
- Adobe Portable Document Format
Licença do Pacote
1 - 1 de 1
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.39 KB
- Formato:
- Item-specific license agreed to upon submission
- Descrição: